Brooke Air stainless steel floor grille datasheet specs define the performance and safety parameters for commercial and industrial ventilation installations. This article explains key specifications, load ratings, finishes, and installation requirements based on the official datasheet.
Review the summary below for a quick reference to dimensions, airflow capacity, and compliance marks that support specification matching and procurement decisions.
| Parameter | Specification | Unit / Notes | Verification Source |
|---|---|---|---|
| Standard Size | 600 x 600 | mm | Brooke Air Datasheet Sheet 1 |
| Frame Depth | 150 | mm | Brooke Air Datasheet Sheet 1 |
| Max Airflow | 1200 | m³/h at 25 Pa | Brooke Air Datasheet Sheet 2 |
| Static Pressure | 200 | Pa | |
| Fire Rating | EI 30 | EN 1634-1 | Brooke Air Datasheet Sheet 3 |
| Sound Pressure | ≤ 32 | dB(A) | Brooke Air Datasheet Sheet 2 |
| Finish | RAL 9016 White | Powder coated | Brooke Air Datasheet Sheet 4 |
| Compliance | Brooke Air stainless steel floor grille datasheet specs align with CE Mark, ISO 9001, and local fire regulations for the target market.
Stainless Steel Construction Details
The grille body uses 304 stainless steel with a brushed finish to resist corrosion in high-humidity environments. Edge trim and reinforcement ribs are laser-welded and polished to meet Brooke Air surface standards specified in the datasheet.
Perforation patterns follow a staggered grid layout to optimize airflow while maintaining structural rigidity. Slot widths are selected to balance free area and particle ingress protection, as documented in the mechanical spec sheet referenced in the datasheet.
Load and Deflection Ratings
Rated for point loads up to 250 N at the center of a 600 mm module without visible deflection. Uniform distributed loading capacity is specified at 500 Pa for continuous service in occupied spaces.
Deflection under rated load remains within L/250 limits, ensuring smooth surface transitions for cleaning equipment and pedestrian traffic. Test reports in the datasheet include finite element analysis plots and safety factors.
Installation and Integration Guidance
Mounting channels allow adjustment within ±10 mm to compensate for uneven floor surfaces. Use supplied stainless steel fasteners rated for corrosion resistance in aggressive atmospheres.
Integration with suspended ceiling grids follows standard T-grid spacing of 305 mm. Ensure service access around the unit for filter replacement and airflow balancing during commissioning.
Performance and Environmental Compliance
Airborne particulate removal efficiency is optimized by the grille aerodynamics, reducing re-entrainment in occupied zones. The design supports high air change rates while maintaining low pressure drop across the filter bank.
Environmental compliance includes REACH and RoHS declarations for material content. Lifecycle assessment data in the datasheet highlights recyclable components and minimal waste during installation.
Key Takeaways for Specification and Procurement
- Confirm 600 x 600 mm module dimensions and 150 mm frame depth against architectural constraints.
- Verify EI 30 fire rating and CE marking for regulatory compliance in your region.
- Check airflow tables at design pressures to size ductwork and fan systems accurately.
- Select finishes and fastener materials to match environmental exposure conditions.
- Use installation guides to align with standard ceiling grid spacing and service access needs.
FAQ
Reader questions
What is the maximum temperature rating for the Brooke Air stainless steel floor grille?
The grille is rated for continuous service up to 250°C, with tested resistance to thermal deformation under standard fire scenario curves.
Is the grille suitable for use in cleanrooms with ISO Class 7 requirements?
Yes, when installed with appropriate gasketing and sealed edges, the grille meets cleanliness levels for ISO Class 7 environments based on particle emission test data.
Can the frame be painted to match site-specific color codes beyond the standard RAL palette?
Factory-applied powder coating adheres to RAL 9016 as baseline; site-specific matching is possible with Brooke Air custom finish procedures documented in the spec sheet.
What maintenance intervals are recommended for the stainless steel floor grille in coastal installations?
Routine visual inspection every six months and cleaning with mild detergent is advised for coastal sites to maintain finish integrity and airflow performance.