The ProStar PRS20053001 Line Regulator delivers precise control for demanding hydraulic applications, supporting a maximum pressure of 3000 psi with a clear, three-gauge display. This compact unit is designed to stabilize inlet and outlet pressures, protecting downstream components from sudden spikes.
Engineered for reliability in field and shop environments, the regulator combines robust construction with user-friendly interface elements. Technicians often specify the PRS20053001 when consistent pressure reporting and safe operation are critical to system performance.
| Model | Max Pressure | Pressure Gauges | Port Size | Connection Type |
|---|---|---|---|---|
| ProStar PRS20053001 | 3000 psi | 3 | 1/4" NPT | 1/4" NPT Inlet, 1/4" NPT Outlet |
| Standard Calibration Range | 0–3000 psi | Pressure Reading | 1/4" NPT | Panel Mount |
| Accuracy | Full Scale ±2% | Setpoint Adjustability | Environmental Rating | Typical Application |
| Response Time | Within 2% Settling | Thread Protection | Mounting Orientation | Mobile Equipment, Testing Rig |
Key Specifications And Performance Metrics
The ProStar PRS20053001 Line Regulator is specified to handle continuous operation at 3000 psi max while maintaining tight control across the pressure spectrum. Each unit includes three pressure gauges that provide real-time insight into system behavior, enabling fast troubleshooting and precise setpoint adjustments.
Designed for demanding mobile and industrial settings, the device balances compact packaging with robust metallurgy. Engineers appreciate the clear gauge layout and reliable repeatability under varying flow conditions.
Operating Pressure Range And Setpoint Control
Setpoint Adjustability Across 3000 psi
Operators can adjust the setpoint smoothly across the full 0–3000 psi range, allowing fine tuning for application-specific requirements. The regulator responds quickly to demand changes without overshoot, preserving system integrity.
Gauge Visibility And Readability
Three pressure gauges deliver immediate visual feedback on inlet, outlet, and system pressure, reducing the chance of misinterpretation. Large dial faces and clearly marked increments support rapid, accurate readings even in low light conditions.
Installation And Integration Guidelines
Proper installation is essential to achieve optimal performance and longevity from the ProStar PRS20053001 Line Regulator. Secure mounting, correct orientation, and appropriate filtration help maintain stable pressure regulation over time.
Technicians should verify port compatibility and ensure that all connections are tightened to specification. Regular inspection of seals and gauges further supports safe, predictable operation in the field.
Final Recommendations For System Protection
- Verify that the inlet pressure does not exceed the 3000 psi maximum rating under any operating condition.
- Use high quality filtration upstream to prevent debris from reaching sensitive internal components.
- Schedule regular inspection and calibration of all three gauges to maintain measurement confidence.
- Follow torque and mounting instructions to avoid stress on ports and housing.
- Document setpoints and response behavior during commissioning to support future troubleshooting.
FAQ
Reader questions
Can the ProStar PRS20053001 handle intermittent peaks above 3000 psi?
No, the regulator is rated for a maximum sustained pressure of 3000 psi; brief overload conditions may damage internal components and void performance guarantees.
How often should the internal filters be inspected or replaced?
Inspect filters at least every 500 hours of operation or per manufacturer guidance, and replace them whenever contamination or pressure drop indicates reduced effectiveness.
What are the recommended maintenance intervals for the three pressure gauges? Verify gauge calibration annually or more frequently in harsh environments, and replace any dial that shows persistent drift, cracks, or readability issues. Is the unit suitable for use with corrosive fluids or gases?
Standard materials are not optimized for aggressive media; consult the specifications or a fluid compatibility chart before exposing the regulator to corrosive substances.