The APC SMX2200RMLV2U Smart UPS X 2200VA 100127V 16A delivers robust protection for critical IT and network equipment. This double-conversion online unit provides 2200 VA of power capacity and intelligent management through an LCD interface and network connectivity.
Designed for small data centers, retail, and office deployments, this model balances compact rackmount capability with advanced power conditioning and scalability. Below you will find detailed specifications, configuration options, and operational guidance tailored for professional users.
| Model | Capacity (VA / W) | Input / Output | Main Features |
|---|---|---|---|
| APC SMX2200RMLV2U | 2200 VA / 1980 W | 384 V Input / 230 V Output | Double-conversion online, hot-swappable battery, scalable runtime, LCD status display |
| Form Factor | 3U Rackmount | Height 132 mm, Width 432 mm, Depth 699 mm | Rack ears, adjustable rails, cable management arms included |
| Battery | Hot-swappable 24 V, user-replaceable | Typical runtime depends on load | Battery warning before expiry, smart online diagnostics |
| Connectivity | USB, RS-232, Ethernet, SNMP, Relay contacts | APC PowerChute network management software compatible | Supports scalable alerting and remote shutdown |
Double Conversion Online Technology
The SMX2200RMLV2U operates in double-conversion online mode, meaning it continuously converts incoming AC to DC and then back to clean AC. This approach isolates connected equipment from input anomalies such as surges, sags, and noise.
Because the inverter always supports the load, transfer times to battery are zero milliseconds. Sensitive equipment in industrial, laboratory, and financial environments benefits from this level of electrical isolation and stability.
Electrical Ratings and Compatibility
With an input voltage range of 384 V and an output of 230 V, this unit fits three-phase high-leg or split-phase installations where appropriate. The 16 A main circuit breaker protects downstream wiring and guarantees safe shutdown in overload conditions.
The 2200 VA rating at full load supports a mix of servers, network devices, and point-of-sale terminals. Understanding actual load in watts helps avoid pushing the UPS to its limits during peak demand.
Installation, Placement, and Environmental Considerations
This 3U rackmount design is intended for vertical installation in standard 19-inch equipment racks or on extended vertical rails. Proper clearance for airflow and service access is critical to maintain reliability and component lifespan.
Operating temperature and humidity ranges must be respected, and ventilation planning must account for heat generated at full load. Correct grounding and adherence to local electrical codes reduce the risk of faults and damage.
Management, Monitoring, and Scalability
Built-in network management allows for remote power cycling, graceful shutdown, and proactive alerts. SNMP and relay contacts enable integration with building management systems or site monitoring platforms.
Multiple SMX units can be installed in parallel to increase capacity and runtime. Hot-swappable batteries allow you to replace modules without taking the load offline, supporting high availability strategies.
Key Takeaways and Recommendations
- Deploy this UPS in environments where zero transfer time and power conditioning are critical.
- Monitor load percentage and plan for future expansion to stay within the 2200 VA rating.
- Use the hot-swappable battery feature to maintain resilience during maintenance.
- Integrate with APC PowerChute for scalable event management and remote control.
- Follow electrical installation standards and verify grounding to ensure safety and compliance.
FAQ
Reader questions
What type of equipment is best suited for the APC SMX2200RMLV2U 2200VA 100127V 16A?
Ideal for small servers, network gear, security systems, and point-of-sale terminals that require robust power protection and zero-transfer downtime in environments with challenging utility power.
Can I replace the battery while the UPS is in service?
Yes, the hot-swappable battery design allows you to remove and install a replacement without powering down the connected equipment or opening the service panel.
How do I configure network alerts and shutdown thresholds on this model?
Use the integrated LCD panel and the free APC PowerChute software to set low-battery warning levels, scheduled shutdowns, and SNMP trap destinations visible on the network management interface.
What should I check before installing this unit in a three-phase high-leg setup?
Verify input wiring configuration, ensure proper grounding, confirm voltage and phase balance, and validate that the connected branch circuit breakers match the 16 A rating specified for safe operation.