Ekko Eraser commercial acoustic panels are designed to control mid and high frequency reflections in dense office environments. These panels combine rockwool core with fabric wrapped cladding to support scalable ceiling and wall solutions for modern buildings.
Facilities teams and acoustic consultants specify these systems when speech clarity, reduced reverb, and compliant fire ratings are non negotiable requirements. The following structure outlines performance, integration methods, and real world expectations for Ekko Eraser in commercial interiors.
| Specification | Ekko Eraser 50mm | Ekko Eraser 100mm | Best Use Case |
|---|---|---|---|
| Core Thickness | 50 mm | 100 mm | Space constrained or high absorption demand |
| Noise Reduction Coefficient | 0.80 | 0.95 | Critical listening areas |
| Fire Classification | A2 s1 d0 | A2 s1 d0 | High occupancy compliance |
| Sustainable Certifications | CE, ISO 14001, EPD available | CE, ISO 14001, EPD available | Green building documentation |
| Typical Coverage Ratio | 25 to 35 percent | 35 to 50 percent | Baseline acoustic targets |
Integration Methods For Modern Offices
Ekko Eraser panels mount directly to ceilings or walls using concealed mechanical fixings that maintain a seamless visual appearance. Coordination with lighting, sprinklers, and service ducts is essential to avoid penetrations that compromise the acoustic seal.
In steel stud partition upgrades, these panels can be layered over existing drywall to increase effective damping without sacrificing floor to ceiling height. Project managers should verify clip spacing and load limits before scheduling installation.
Material Performance Under Real Loads
The rockwool core maintains stable absorption across temperature and humidity shifts, supporting long term consistency in performance. When paired with perforated metal facades, the system can extend the effective air gap for low frequency enhancement.
Cleaning procedures are limited to light dusting and occasional vacuuming with soft brush nozzles to prevent fabric damage. Harsh chemicals or abrasive tools are discouraged to preserve Class 1 surface durability ratings.
Design Flexibility For High Traffic Zones
For lobbies, atriums, and open plan workstations, Ekko Eraser offers modular sizes and edge trims that align with architectural grids. Color options allow branding alignment while still meeting acoustic target curves.
Acoustic modeling software can simulate panel coverage to balance cost and performance, particularly where budget ceilings restrict full surface treatment. Specifying the 100 mm variant in zones with high speech privacy demand often reduces the need for additional sound masking systems.
Acoustic Metrics And Compliance Pathways
Test data shows strong performance in reverberation reduction for speech frequencies, which translates into measurable improvements in employee focus and call center clarity. Documentation packages typically include ISO 11654 classification curves and field NRC validation reports.
Projects targeting WELL, BREEAM, or ISO workplace standards can reference these metrics directly in their acoustic sections. Designers should cross check local building codes to ensure mounting details and fallback materials satisfy regulatory review.
Key Takeaways For Acoustic Specification
- Select 100 mm thickness for spaces where ceiling height permits and target NRC above 0.9
- Verify fire classification and local code alignment before finalizing panel choice
- Model panel coverage early to balance acoustic goals against budget constraints
- Coordinate mechanical and lighting layouts to avoid compromising the acoustic boundary
- Plan maintenance procedures to preserve fabric surface and long term absorption
FAQ
Reader questions
How do Ekko Eraser panels compare to standard mineral fiber tiles in commercial acoustics?
Ekko Eraser delivers higher NRC values, better low frequency control with added air gap, and documented fire performance that often exceeds standard mineral fiber tiles, which can sag or degrade humidity sensitivity over time.
Can these panels be used in suspended grid systems without replacing the entire ceiling?
Yes, they are compatible with most standard lay in grid frames when specified with the correct clip kit, though layout coordination with vents and luminaires is critical to maintain acoustic continuity and avoid gaps.
What maintenance schedule is recommended for high traffic commercial spaces?
Routine maintenance should include quarterly visual inspection for dust buildup and gentle vacuuming with brush attachments; deeper cleaning is only required in areas with heavy particulate exposure, following manufacturer guidance to protect fabric integrity.
Are Ekko Eraser panels suitable for exterior or damp environment applications?
These panels are primarily designed for interior use; exterior or high humidity conditions require additional protective membranes or specified waterproof variants, along with proper drainage and ventilation details to prevent fiber saturation.